Hodžův blog

Archive for the 'virtualizace' Category

29 Srp

Greenbone Enterprise TRIAL – Login problem

With Greenbone Enterprise TRIAL, as well as Greenbone Community Edition (GCE), I ran into a problem where I could not log into the web interface after several tests. I just get a message: The Greenbone Vulnerability Manager service is not responding. This could be due to system maintenance. Please try again later, check the system […]

07 Čvn

HowTo: Upgrade Intel NVMe P4600 SSD firmware in ESXi 7

Download and install Intel® Memory and Storage Tool CLI Solidigm™ Storage Tool CLI (SST) [root@vmware:~] /opt/solidigm/sst/sst load -ssd 0 WARNING! You have selected to update the drives firmware! Proceed with the update? (Y|N): y Checking for firmware update… – Intel SSD DC P4600 Series PHLE729000X14P0KGN – Status : The selected drive contains current firmware as […]

02 Čvn

Proxmox – Could not login to web interface and read only directory /etc/pve

May 29 02:06:55 pve1 pvestatd[1931]: authkey rotation error: cfs-lock ‚authkey‘ error: got lock request timeout May 29 02:06:55 pve1 pvestatd[1931]: status update time (9.120 seconds) May 29 02:06:56 pve1 pve-ha-lrm[2050]: unable to write lrm status file – unable to delete old temp file: Input/output error Fix the cluster filesystem: # systemctl stop pve-cluster # rm […]

06 Čvn

Change Hyper-V IP addres in Synology Active Backup for Business

1. Enable SSH 2. Sign as root user 3. Run SQLite3 sqlite3 /volume1/\@ActiveBackup/config.db 4. Determine inventory_id: sqlite> SELECT inventory_id, host_name, host_addr FROM inventory_table; 1|172.26.1.3|172.26.1.3 5. Update IP address and host name (on row with correct inventory_id): sqlite> update inventory_table set host_name = „172.26.1.3“, host_addr = „172.26.1.3“ WHERE inventory_id = ‚1‘; 6. Terminate SQLite3 program: sqlite> […]

20 Led

Error installing VMware Remote Console plugin – (k)ubuntu 18.04

Quick Fix # apt-get install desktop-file-utils

17 Led

„The Ext Drive has been disabled due to a detected fault“ Lenovo SR570 & Lenovo DE4000H

1. Power off (all) servers 2. Change the volume LUN ID to ID 0 on DE4000H 3. Power on (all) servers

24 Zář

Error „Hardware RAID is disabled via NVRAM Controller setting“

# Show controller slots ssacli ctrl all show config # Disable HBA Mode ssacli controller slot=0 modify hbamode=off # Recheck controller status ssacli controller slot=0 show

12 Led

VMware VMRC fails to install on Debian or (K)Ubuntu Linux

It appears, that update-desktop-database was not installed by default. After an apt-get install desktop-file-utils VMware Remote Console installs without error.

12 Led

Veeam Agent – reset backup jobs (re-create the Database )

Perform the following actions: 1. Run regedit.exe and locate the HKEY_LOCAL_MACHINE\SOFTWARE\Veeam\Veeam Endpoint Backup key. Create the following value under this key:Name = Recreatedatabase Type = DWORD Value = 1  2. Go to Control panel > Administrative Tools and run Services. Restart the Veeam Agent for Microsoft Windows service. A new database instance will be created (this usually […]

04 Lis

HowTo: HP ILO – There are pending changes that may not take effect until ILO is reset.

Reset the interface through SSH. ssh root@my.hp.ilo cd /map1 reset

Hodžův blog is is proudly powered by Wordpress and the Magellan Theme